Photometric Analysis & Lighting Layout Beta
Pick the space, choose a fixture or load an IES file, then lay out fixtures and see point-by-point footcandles update as you go.
Numeric grid (fc at each calculation point)
Rows run north (top) to south; values below the target minimum are red. Points in the edge band are in grey.
How this calculation works
Direct light, point by point. For each calculation point on the workplane and each fixture: E = I(γ,ψ) × cosγ / d² = I × h / d³, where I is the candela from the IES table at the vertical angle γ (0° = straight down) and horizontal angle ψ (measured counter-clockwise from the fixture's 0° axis, which turns with the fixture), h is the fixture height above the workplane and d the straight-line distance. Candela between table angles is interpolated linearly in both directions, and the file's symmetry (rotational, quadrant, bilateral, full) is honored. Each fixture is scaled by (its lumens / the file's lumens) × ballast factor × LLF.
Interreflected light (interior only, optional). A simple uniform estimate, not a radiosity solution: the direct flux on the workplane comes from the point grid; the rest of the downward flux lands on the walls above the workplane and any upward flux lands on the ceiling. The first reflection from those surfaces is then spread over the room cavity with the integrating-sphere relation Eir = Φreflected / (Atotal × (1 − ρavg)), and that one value is added to every point. Obstructions, furniture and partitions are not modeled.
Site. Direct light only; no reflections. Points outside the area outline are not calculated.
Results. Min, max and average use the points inside the area (less the edge band, if set). Avg:min = average / minimum and max:min = maximum / minimum. The lumen-method line is a cross-check: N = E × A / (lumens × CU × LLF).
Where it runs. The plan recalculates in this page as you edit (the same method and numbers as the engine). Run on the OTW Apps engine gives the official result with the PDF, CSV and DXF; Auto-layout runs on the engine for signed-in members. Every table and default (targets, fixtures, defaults, color bands) lives in the engine's CSV data files; Edit data tables changes them for this session.
Not covered: vertical illuminance, tilted fixtures, glare (UGR), light trespass at property lines, emergency egress lighting, energy-code lighting power limits, and SI units.