OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Power Factor Correction Calculator Power triangle (IEEE Std 141 Ch. 8); NEC Art. 460 installation

Power triangle equations

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

Enter real power in kW and power factors as decimals (0.85, not 85 %).

How this calculation works

Equations only (the power triangle, as in IEEE Std 141-1993, Ch. 8). No code table is used.

  • phi = acos(PF); reactive power Q = P x tan(phi); apparent power S = P / PF.
  • Required capacitor kVAR Qc = P x (tan(phi1) - tan(phi2)), with PF1 the existing and PF2 the target power factor.
  • Assumes a balanced, sinusoidal, lagging load at constant real power; harmonics and resonance are not considered.
  • Choose a standard capacitor rating at or above Qc and check for over-correction at light load.
  • Not covered: capacitor installation (disconnects, conductors, overcurrent protection, discharge), which follows NEC Article 460 as adopted where the work is done.

Related apps

  • Voltage Drop
  • Dwelling Service Load
  • Conductor Ampacity & Sizing
  • Transformer Size & Protection
  • Available Fault Current
  • All Electrical apps
OTWapps
About Methods & references View plans Privacy Terms

Engineering aid only. Professional verification required.