OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Motor Branch Circuit Calculator (NEC 2023 Article 430, single motor)

Motor (all required)
Conductor and protection (all required)
Advanced: full detailed inputs

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

Guide: OTW Motor Branch Circuit (NEC 2023 Article 430, single motor)
  1. Load an example to see the expected inputs, then replace every example value with your project data.
  2. Work through the input sections in order. Confirm the displayed units, selected method and applicable code.
  3. Use Detailed calculation inputs for additional settings and nested rows. Add or remove rows without editing code.
  4. Run the calculation, then review the governing check, assumptions, warnings and detailed results. Verify the result before using it in a design.
Code edition and design decisions (NEC 2023)

Code edition: NEC (NFPA 70) 2023: 430.6(A) full-load current from Tables 430.247 (DC), 430.248 (single-phase) and 430.250 (three-phase), 430.22 conductor, Table 310.16 with 110.14(C), 430.32 overload, Table 430.52(C)(1) with 430.52(C)(1)(a) and (b) (the 2020 Exceptions 1 and 2) and 430.52(C)(3), 240.6(A) (2023 list, which includes 10 A), 430.110(A) and 430.109 disconnect. This is not the printed NFPA 70-2023: table values and rule text come from reproductions that agree with each other (see the notes).

  • Required inputs, no defaults: motor type, horsepower, rated motor voltage, nameplate FLA, service factor (enter 1.00 if none is marked), temperature rise (a number in C, or "other" if not marked), conductor material, termination temperature rating and device type. Only the project name is optional. Unknown keys, true/false values and out-of-range values are rejected.
  • FLC from the table, never the nameplate (430.6(A)(1)), by horsepower and the rated motor voltage column: 115, 200, 208, 230, 460, 575 V (three-phase); 115, 200, 208, 230 V (single-phase); 90, 120, 180, 240, 500, 550 V (DC). A 480 V system uses the 460 V column. A horsepower and voltage the table has no value for are rejected. The 2300 V column is not stored.
  • Conductor: at least 125 % of FLC (430.22), the smallest Table 310.16 size whose termination column (60, 75 or 90 C, as you enter) reaches it, one conductor per phase. Ambient correction and conductor-count adjustment are not applied; if no single size up to 2000 kcmil is large enough the result says so.
  • Overload uses the nameplate FLA: 125 % if the service factor is 1.15 or more or the temperature rise is 40 C or less, otherwise 115 %; the 430.32(C) maximums (140 % and 130 %) are shown as well. The same percentages are used for 1 hp or less: 430.32(B)(1) (automatically started) and 430.32(D) via (B) (nonautomatically started, permanently installed or controller not in sight). A manually started motor of 1 hp or less that is not permanently installed and has its controller in sight may rely on the branch-circuit device (430.32(D)). Thermal protectors, integral and impedance protection are not modeled.
  • Short-circuit and ground-fault device: Table 430.52(C)(1) percent of FLC: nontime-delay fuse 300 %, dual-element fuse 175 %, instantaneous-trip breaker 800 %, inverse time breaker 250 % (single-phase and polyphase squirrel-cage); DC motors 150 %, 150 %, 250 %, 150 %. 430.52(C)(1)(a): if the value is not a standard rating the next higher standard rating of 240.6(A) is permitted, and 10 A is the smallest standard breaker rating (not for an instantaneous-trip setting). The 430.52(C)(1)(b) maximums (the old Exception 2) are shown for information only; for a nontime-delay fuse whose 400 % value would exceed 600 A the 300 % ceiling of fuses of 601 to 6000 A is shown. The result is a maximum: also respect the controller and overload relay manufacturer tables.
  • Disconnect: at least 115 % of FLC and rated in horsepower for the motor (430.110(A), 430.109); a listed unfused motor-circuit switch rated in horsepower not less than the motor may have an ampere rating below 115 % (430.110(A) exception).
  • Exact arithmetic: every number is exact and shown without rounding, so a flag always agrees with the number beside it.
  • Not covered: multiple motors (430.24, 430.62), feeders, synchronous motors (Table 430.250 has separate synchronous columns), wound-rotor and Design B energy-efficient / premium efficiency special rows of Table 430.52(C)(1), motors built for low speeds (under 1200 RPM) or high torque, multispeed and canned-pump motors (the nameplate current governs for these, 430.6(A)(1)), torque motors, short-time and intermittent duty, drives, motors above 600 V, conduit fill and voltage drop.

Related apps

  • Voltage Drop
  • Power Factor Correction
  • Dwelling Service Load
  • Conductor Ampacity & Sizing
  • Transformer Size & Protection
  • All Electrical apps

Guides

  • How to calculate voltage drop with NEC Chapter 9 tables