Sign Wind Load Calculator Monument, pylon, billboard and wall signs. ASCE 7-22 Ch. 29 / FBC 2023 Sec. 1609
How to use: Sign Structures
Pick the sign type: Monument, Pylon, Billboard or Wall.
Type your numbers in the boxes. An example is already filled in. Replace it with yours.
Need another setting? Open More options.
Press the “Check the sign” button.
Read the results. Green bars pass. Red bars do not pass.
What it does
Finds the wind force on the sign and checks what holds it up: posts, pier, footing or wall anchors.
Good to know
Units: feet, inches, pounds, mph.
Wind speed: from the wind map for your Risk Category (ASCE 7-22 / FBC 2023).
Sign weight: the whole sign, with its frame.
Monument: sits on a concrete footing at grade.
Pylon and billboard: steel pipe or HSS posts set in a round concrete pier. Pick “Lightest that works” and the app picks the post.
Billboard faces: two back-to-back faces add weight, not wind.
Wall: pick the wall type, the fastener type and the size. The app works out what each fastener can hold.
Concrete wall: adhesive anchor with threaded rod. Uses the lowest code bond values (ACI 318-19), cracked concrete, f′c 3,000 psi, and the shallowest normal embedment. The results list the edge distance, spacing and wall thickness it assumes.
Wood stud wall: lag screw or wood screw into the studs (NDS 2018). Assumes Spruce-Pine-Fir studs at 16 in., a 14 ga steel bracket tight on the wall, and 2-1/2 in. (lag) or 1-1/2 in. (screw) of thread in the stud.
Deeper embedment or stronger concrete: change it under More options.
Not offered yet: wedge anchors and concrete screws, block (CMU) walls and steel stud walls. Their strength depends on the product’s test report. The building wall itself is not checked.
Not covered: open or lattice signs (30% open or more), W-shape or wood posts, base plates, seismic, ice, deflection.