OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Sanitary Sewer Calculator Ten States Standards, Recommended Standards for Wastewater Facilities (2014)

Ten States Standards, Recommended Standards for Wastewater Facilities (2014)
This app is temporarily unavailable.

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

US customary units (gpd, cfs, ft, in).

Method, assumptions and limits
  • Design aid, not a design. The results are engineering aids. A licensed engineer must review them before sealing. The flow, peaking, infiltration/inflow and roughness inputs control the answer, and the reviewing agency's standards govern.
  • Design flow. Average daily flow = population x per-capita flow (+ other average flow), or a direct value. Design (peak) flow = average flow x peaking factor + infiltration/inflow allowance. The allowance is added after peaking (it is not peaked). The per-capita flow is an input; if blank the app uses 100 gal/cap/day (Ten States Sec 11.243), shows it under defaults used and warns.
  • Peaking factor. Default: Ten States Standards (2014) Fig. 1, PF = (18 + sqrt P)/(4 + sqrt P) with P in thousands (the Harmon form 1 + 14/(4 + sqrt P); ASCE MOP 60 / FD-5 Eq 6-12). Babbitt PF = 5/P0.2 (after Babbitt and Baumann (1958); stated range 1 to 1000 thousand persons, warned outside it) or a fixed factor are selectable. The curve spans populations of about 100 to 100,000 (outside it the factor is extrapolated and warned). If you leave the method blank, harmon is used and the page warns. P is the tributary population of the pipe you are checking. Other average flow is added before peaking and the residential population sets the factor (a judgment call): that is conservative for a steady flow, but not for a short, large load (shift change, batch discharge) whose own factor is above the residential one; the result carries a note when other flow is entered.
  • Infiltration/inflow. The Ten States curve is stated to cover normal infiltration; an additional allowance is made where conditions are unfavorable (Sec 11.243). Enter it as gpd per inch-diameter-mile, gpd per acre, a total, or a percent of average flow. With nothing entered it is 0 and warned.
  • Hydraulics. Manning V = (1.486/n) R2/3 S1/2 for a circular pipe flowing partly full (ASCE MOP 60). The normal depth at the design flow is found by bisection on the rising branch of the discharge curve. The design flow must not exceed the full-pipe discharge (a flow between full flow and the maximum open-channel discharge at d/D 0.94 is reported as surcharged). Depth, velocity, d/D, Froude number and the tractive stress at average flow are reported; average-flow depth leaves out the infiltration/inflow allowance.
  • Constant n is the default, and why. ASCE MOP 60 / WEF FD-5 Sec 5.4.4 shows the Darcy-Weisbach n is essentially constant for y/D above about 0.15 and says that Camp's (1946) variation of n with depth is in error; Ten States uses n = 0.013 throughout. n_model variable applies the FD-5 Darcy-Weisbach shape ratio (Eq 5-22 Swamee-Jain f, Eq 5-31 n = 0.0926 R1/6 f1/2, water at 60 F) with your n as the full-pipe value; n_model camp applies the legacy Camp ratios. Both are for comparison.
  • Ten States checks (Chapter 30). 33.1 public sewer at least 8 in. 33.41: full-pipe velocity at least 2.0 ft/s with n = 0.013 whatever n you entered (3.0 ft/s for 48 in and larger), and the recommended minimum-slope table for 8 to 42 in; the table slopes are a little steeper than the pure 2 ft/s slope for small pipes (8 in: 0.40 against 0.334 ft/100 ft), so both are shown. 14 in and 16 in are not in the Ten States table (state adaptations use 0.17 and 0.14; 35 Ill. Adm. Code 370, 9VAC25-790-320). 33.42: a slightly flatter slope may be considered where the depth is at least 0.3 D at design average flow, with written assurance from the operating authority: the slope row stays FAIL (its text points to this exception) and the average-flow depth is shown. 33.43: if the slope is below the minimum of the smallest pipe that can carry the flow, depths and velocities at minimum, average, max-day and peak flow are required (average, peak and, if you enter a minimum ratio, minimum are reported). 33.45: velocity over 10 ft/s needs special provisions against scour and displacement. 33.46: slopes of 20 percent or more need anchors. These two rows read SPECIAL PROVISIONS REQUIRED rather than FAIL (the standard allows the design with those provisions), but they still gate the status: it is FAIL, never PASS, until they are made, and the status detail says when they are the only rows failing.
  • Size selection (diameter left blank). The smallest nominal size from 8 in that meets the capacity, the depth limit, the 2 ft/s velocity and the slope table and needs no special provision. A size that avoids the 10 ft/s or 20 percent row is preferred only if it is at most 2 nominal sizes larger (an oversized sewer is itself a Ten States 33.43 problem; at a fixed flow and slope the velocity falls only slowly with diameter). Otherwise the smallest size meeting the other checks is returned with status FAIL and a warning. If no standard size satisfies the other checks the run is rejected with "no standard size satisfies all checks".
  • Design depth. FD-5 Sec 6.9: sewers up to 15 in are often designed half full and larger ones three-quarters full. That is practice, not a Ten States rule, so the depth limit is an input; without it that row is NOT CHECKED and the status is INCOMPLETE. Size selection needs it.
  • Checks against published values. Checked against independent hand calculations. The Ten States Fig. 1 factors, the 0.6 m/s minimum slopes in SI and the d/D = 0.67 circular partial-flow ratios agree. The Illinois full-flow capacities at the minimum slopes (8 in 0.49 mgd to 42 in 12.41 mgd) agree within 0.94% over 14 rows (the printed values are two-decimal figures). The FD-5 4 in at 0.0075 serving "about 50 houses" agrees only loosely: the full-pipe capacity corresponds to 44.4 houses and the open-channel maximum to 47.7, and 50 houses is surcharged under this app's rule.
  • Out of scope. Force mains and pumping, manhole and junction losses, drop manholes, surcharge and hydraulic grade line, diurnal and dry-weather flow patterns, networks (run each pipe with its own tributary population), self-cleansing design by tractive force or sediment type, non-circular pipes, structural design, sulfide and odor, and state or local standards that differ from Ten States.
  • Fields: misspelled or unknown fields are rejected, not ignored. Numbers must be numbers. Values outside sane bounds are rejected, including flows too small to solve (population and per-capita flow at least 1, direct average flow at least 1 gpd, minimum-flow ratio at least 1e-6).

Related apps

  • Lift Station
  • Full Lift Station Design
  • Full Site and Stormwater Design
  • Peak Runoff (Rational Method)
  • Stormwater Runoff (TR-55)
  • All Civil / Site apps