OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Grass-Lined Channel & Swale Calculator FHWA HEC-15, vegetative lining

FHWA HEC-15
This app is temporarily unavailable.

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

SI or US customary units: choose them in the form (no default).

Method, assumptions and limits
  • Design aid, not a design. The results are engineering aids. A licensed engineer must review them before sealing. The grass, soil and design-flow inputs control the answer and must be verified for the site; HEC-15 advises designing for capacity with the densest, tallest grass and for stability with the poorest anticipated cover: run both.
  • Method (default, and why). FHWA HEC-15, 3rd ed. (FHWA-NHI-05-114, 2005) vegetative linings. It is the current FHWA method, it is a function of measurable grass properties (stem height, density-stiffness Cs, cover factor Cf) and of the soil, it checks erosion of the soil under the grass (not only velocity), and it has published SI and CU examples that this app reproduces. Manning n is not fixed: Cn = alpha Cs0.10 h0.528 (Eq 4.1), n = alpha Cn tau_o-0.4 (Eq 4.2) with the mean boundary shear tau_o = gamma R So (Eq 2.3), so n falls as the flow deepens. The normal depth is solved exactly by bisection (to 1e-12), not by the 5 percent hand procedure of Sec 3.1; the printed example depths are rounded hand iterations and differ by a few percent, the printed shear checks are reproduced.
  • Stability. Maximum shear tau_d = gamma d So (Eq 3.1; conservative for B/d under 4). Permissible shear on the grass tau_p = tau_p,soil / (1 - Cf) x (n / ns)2 (Eq 4.7, with Eq 4.3). The lining passes when tau_p is at least SF x tau_d (Eq 3.2). SF defaults to 1.0 (HEC-15 Sec 3.1), is echoed and warned; 1.0 to 1.5 is suggested for supercritical flow, uneven or slow vegetation, uncertain Q or high consequence of failure. The computed SF is reported.
  • Soil. Non-cohesive (PI under 10): D75 under 1.3 mm (0.05 in) gives 1.0 N/m2 (0.02 lb/ft2) and ns 0.016; larger D75 uses Eq 4.5 and Eq 4.4. Cohesive: Eq 4.6 with Table 4.6 (ASTM class, PI, void ratio). A direct permissible soil shear overrides the calculation (a warning names the soil class, PI and void ratio that are then ignored). If neither D75 nor ns is given, ns = 0.016 (fine soil) is used and warned. Note that the HEC-15 maximum-discharge example prints ns = 0.016 for D75 = 2 mm (Eq 4.4 gives 0.0168): enter grain_roughness 0.016 to match it.
  • Sides, bends, freeboard. Side shear K1 tau_d (Eq 3.3 and 3.4) must also stay under tau_p / SF. Side slopes steeper than 1:3 fail for non-cohesive soil and are warned for cohesive soil (Sec 3.2). Bends (optional radius of curvature to the centerline): Kb tau_d (Eq 3.6 and 3.7), superelevation V2 T / (g Rc) (Eq 3.9), protection length (Eq 3.8). Freeboard (Sec 2.3.4) is at least 0.15 m (0.5 ft), or the whole flow depth where the flow is supercritical, and needs a channel depth; the top width to depth ratio is advisory: above about 20 (HEC-15 Sec 2.3.2, “less than about 20”) it is a warning, not a failed check. A row with no result (“NOT CHECKED”) means the input was not given; the status is INCOMPLETE, never a pass.
  • Top width to depth (T/d). HEC-15 Sec 2.3.2 limits channel width to a T/d “less than about 20” because very wide channels form smaller channels within their banks. That is guidance, so from 20 up to 40 the row passes with a warning. Above 40 the row fails: 40 is an app convention (twice the HEC-15 guidance), not an HEC-15 figure. Provide a low-flow channel, a stiffer lining or a narrower section.
  • Maximum discharge. The largest depth where SF tau_d equals tau_p is solved exactly and Q computed; the approximate HEC-15 Eq 4.8 estimate is shown beside it. The maximum is returned with every analysis, too.
  • TP-61 cross-check (optional, never changes the status). The classic SCS TP-61 retardance classes A to E in the Temple et al. (1987) USDA Handbook 667 equation (a regression of the TP-61 n-VR curves, not the digitized figures). It gives n and the normal depth for the class you pick; a depth difference over 25 percent is warned, and so is a result that does not satisfy Q = V A (the class A curve is multi-valued for some flows: the cross-check is then unreliable). It has no soil or stability check, and the class is itself a judgment, which is why it is not the default.
  • Out of scope. Composite and multi-layer linings, steep-slope design, RECP and turf reinforcement mats, riprap and gravel linings, low-flow flow below the stem height (warned), sediment, check dams, culverts, driveways, and state or local drainage standards.
  • Fields: misspelled or unknown fields are rejected, not ignored. Numbers must be numbers. Values outside sane bounds are rejected, including a stem height under 0.005 m (0.015 ft) and a parabolic top width under 0.05 m (0.15 ft).

Related apps

  • Gutter Spread & Inlet Capacity
  • Outlet Structure Rating
  • Riprap Outlet Protection
  • Storm Pipe Sizing
  • Culvert Capacity & Sizing
  • All Civil / Site apps
OTWapps
About Methods & references View plans Privacy Terms

Engineering aid only. Professional verification required.