Full Site and Stormwater DesignBeta
NRCS NEH 630 / TR-55, FHWA HEC-22, NOAA Atlas 14, FDOTNRCS curve number and unit hydrograph, Muskingum-Cunge reaches, storage-indication ponds
Members: OTW Pro or OTW TeamPaid plan
Search by app name, task, or discipline.
NRCS curve number and unit hydrograph, Muskingum-Cunge reaches, storage-indication ponds
Members: OTW Pro or OTW TeamPaid plan
Rational Method peak flow Q = CiA with weighted C, IDF input and Tc by Kirpich, TR-55 or FDOT kinematic wave; 5-min floor default.
3 free calculations
NRCS TR-55: composite curve number, runoff depth, time of concentration by segment, and graphical peak discharge.
3 free calculations
Cut and fill volumes by average end area or cross-section coordinates, prismoidal correction, shrink and swell, mass diagram, grid method.
3 free calculations
HEC-22 gutter flow and spread, and grate, curb-opening, slotted and combination inlet capacity on grade and in sags, with bypass.
3 free calculations
Outlet structure rating per HEC-22 Ch. 10: orifice, weir, V-notch and riser flow, composite stage-discharge, tailwater submergence.
3 free calculations
HEC-14 riprap outlet protection for culverts and pipes: apron or basin, stone size D50, length, width, thickness, gradation class.
3 free calculations
HEC-15 grass-lined swale and roadside ditch design: normal depth, velocity, Froude number, permissible shear of the grass and soil, freeboard and maximum discharge.
3 free calculations
Check ramps, walking surfaces and curb ramps against the 2010 ADA Standards or PROWAG 2023: slopes, landings, widths, handrails.
3 free calculations
Storm pipe and box sizing by Manning full and partial flow: required diameter, next standard size, normal and critical depth, velocity checks.
3 free calculations
Culvert inlet and outlet control per FHWA HDS-5: governing headwater, HW/D checks, outlet velocity and size selection.
3 free calculations
Detention pond routing by the storage-indication (modified Puls) method per FHWA HEC-22 and HDS-2: inflow hydrograph, stage-storage, orifice, weir and spillway outlets.
3 free calculations
Open-channel Manning flow for trapezoid, rectangle, triangle and circular sections: normal depth, discharge, velocity, Froude number and critical depth.
3 free calculations
AASHTO 1993 pavement design: flexible structural number and layer thicknesses, rigid slab thickness, and design ESALs from axle loads.
3 free calculations
AASHTO Green Book 2018 crest and sag vertical curves: stopping and passing sight distance, K values, minimum length, PVC/PVT stations, high or low point and profile elevations.
3 free calculations
Ten States Standards and ASCE MOP 60 sanitary sewer capacity: average and peak flow, infiltration/inflow, depth and velocity at peak, average and minimum flow, minimum slope, and pipe size selection.
3 free calculations
Parking app: required spaces from the ratios you enter (mixed uses, shared parking), accessible and van spaces per the 2010 ADA Standards 208.2, EV-ready count and a stall and aisle layout check for 90, 60, 45 and 30 degree parking. No local code table is built in.
3 free calculations
Fire service line hydraulics, NFPA 13 and NFPA 24 practice: Hazen-Williams friction with equivalent lengths, backflow and meter losses, elevation, hydrant flow test supply curve (N^1.85) and the safety margin at the base of the riser.
3 free calculations
Modified Rational Method detention volume: critical storm duration search with inflow trapezoid, allowable release (entered or pre-development Rational peak), documented outflow assumption, duration table and step-by-step citations.
3 free calculations
Force main losses and velocity, total dynamic head, wet well volume and pump levels, cycle time, detention, pump operating point and buoyancy.
3 free calculations
Duplex or triplex submersible station: pump and system curves, wet well levels, cycle time, force main checks and a sheet set
Members: OTW Pro or OTW TeamPaid plan
ASCE 7-22 and FBC 2023 main wind force resisting system pressures: Kz, Kzt, Ke, qh, directional and low-rise envelope, minimum case, with ASD 0.6W.
3 free calculations
ASCE 7-22 and FBC 2023 components and cladding wind pressures by zone and effective wind area, with ASD 0.6W.
3 free calculations
Every ASCE 7-22 Chapter 2 LRFD and ASD load combination, with governing max and min and the code section on each line. IBC/FBC 1605.
3 free calculations
Minimum floor and roof live loads by structure type, from FBC 2023 Table 1607.1 (ASCE 7-22 loading), with a one-page PDF.
3 free calculations
NDS 2024 checks for sawn, glulam and LVL beams, joists and headers: bending, shear at d, bearing and deflection with creep.
3 free calculations
NDS 2018 wood post and column check: axial with column stability factor CP, bearing, and combined bending and axial. ASD and LRFD.
3 free calculations
Sawn-lumber joist and rafter span check to NDS 2018: bending, shear, bearing, live and total deflection, max allowable span.
3 free calculations
AISC 360-22 W-shape beam check: yielding, lateral-torsional buckling with Cb, flange local buckling, shear and deflection. LRFD/ASD.
3 free calculations
AISC 360-22 steel column check for W shapes, HSS and pipe: compression (Chapter E) and combined axial and flexure (H1).
3 free calculations
ASCE 7-22 Sec. 12.8 equivalent lateral force: SDC, Cs and its limits, base shear, story forces, overturning and drift.
3 free calculations
ACI 318-19 isolated spread footing: bearing with lift-off, one-way and punching shear, flexure and reinforcement.
3 free calculations
Cantilever reinforced-concrete retaining wall: IBC 2024 / FBC 2023 1807.2.3 stability and bearing, ACI 318-19 stem, toe and heel design.
3 free calculations
Plane truss analysis by the direct stiffness method: Pratt, Howe, Fink, scissor and king-post generators or custom geometry, member forces, reactions and deflection.
3 free calculations
Monument, pylon, billboard and wall signs: ASCE 7-22 Ch. 29 wind on the sign, steel posts and piers, monument footings, and wall anchors or screws.
3 free calculations
ASCE 7-22 Chapter 7 roof snow loads: flat, sloped, minimum, rain-on-snow, unbalanced and drift loads.
3 free calculations
Wood structural panel shear walls (segmented and perforated) and diaphragms per AWC SDPWS-2021, ASD and LRFD for wind and seismic.
3 free calculations
Cubic yards for slabs, footings, walls and columns, with a waste factor, order quantity and bag counts.
3 free calculations
Bar counts by spacing, bar lists, laps and stock lengths, and weight in pounds and tons for #3 to #18 bars.
3 free calculations
Flexure, shear and stirrups, bar spacing, cover, minimum depth and deflection for rectangular and T-beams.
3 free calculations
Runway beams for bridge cranes: crane impact and lateral loads, moving wheel moments, biaxial bending, web local checks, deflection and fatigue.
3 free calculations
Axial capacity of one helical pile or anchor: helix bearing in clay or sand, torque correlation, product limits, allowable load and required installation torque.
3 free calculations
Loads on one roof attachment of a rail-mounted PV array and lag screw withdrawal into the rafter, with the attachment maker's rated values.
3 free calculations
Out-of-plane check of a solid tilt-up or precast panel strip: P-delta magnified moment, phi Mn, axial limit and service deflection.
3 free calculations
Loads on one ground-mount pile, embedment for lateral load by IBC Eq. 18-1, uplift by skin friction and compression.
3 free calculations
Wind on a solid or mostly solid fence or freestanding wall: Case A line posts, Case C end zones, post bending and footing embedment.
3 free calculations
Draft clear-span gable rigid frame with prismatic members. Not an MBMA design.
3 free calculations
NDS dowel-yield modes and withdrawal for nails, screws, lags, and bolts.
3 free calculations
Concentric axial compression plate thickness after AISC Design Guide 1. Anchor design is out of scope.
3 free calculations
NEC Chapter 9 Tables 8 and 9 voltage drop for 1-phase, 3-phase and DC, Cu or Al, parallel sets, and minimum size for a target.
3 free calculations
Capacitor kVAR to raise a load from its existing to a target power factor, with kVA before and after, from the power-triangle equations.
3 free calculations
NEC 2023 Article 220 standard method for one dwelling: lighting, appliances, range, dryer, EVSE, heating or cooling, service size.
3 free calculations
Number of luminaires for a target average illuminance by the lumen method, with the achieved illuminance. You enter CU and LLF from product data.
3 free calculations
NEC 2023 Table 310.16 conductor sizing for Cu or Al: 125% continuous load, ambient and more-than-3-conductor adjustment, 110.14(C) termination limit and 240.4(D) small-conductor limits.
3 free calculations
NEC 2023 450.3(B) transformer sizing and primary/secondary overcurrent protection for 1-phase and 3-phase units 1000 V or less, with standard 240.6(A) ratings and optional secondary conductors.
3 free calculations
Available fault current by the Eaton/Bussmann point-to-point method: transformer FLA and multiplier with %Z tolerance, optional motor contribution and f/M factors at each downstream point.
3 free calculations
Required box volume by the NEC 314.16(B) counting rules, pass/fail for a chosen box and the smallest standard metal box.
3 free calculations
Percent fill and the smallest trade size for mixed conductors in EMT, PVC, RMC and other raceways, NEC Chapter 9.
3 free calculations
Single-motor branch circuit: table FLC, conductor, overload, short-circuit and ground-fault device and disconnect, step by step.
3 free calculations
EGC by OCPD rating with the 250.122(B) increase, and GEC by service conductor size with the electrode limits.
3 free calculations
Point-by-point illuminance from IES photometry, interactive fixture layout, interior and site
Auto-layout is included with OTW Pro and OTW Team.3 free calculations
Cold-weather Voc, modules in series against the inverter and MPPT window, system voltage limit and 690.8 circuit currents.
3 free calculations
DC and AC resistance, reactance and effective Z for one conductor, corrected to temperature, and the ohms of a run. Voltage drop: the Voltage Drop app.
3 free calculations
Equal-friction duct sizing: round size, velocity, friction rate and the rectangular equivalent for each segment, by the ASHRAE Duct Design method.
3 free calculations
Required exhaust airflow by space type or your own rates, plus a clothes dryer duct length check against the 35 ft limit, with a hand-off to Duct Sizing.
3 free calculations
Outdoor air by the ventilation rate procedure: pick occupancies and air distribution by name for Vbz, Voz and system outdoor air, with the multi-zone system efficiency equations.
3 free calculations
Moist-air properties from dry bulb and one of RH, wet bulb, dew point or humidity ratio: enthalpy, humidity ratio, dew point, specific volume, by the ASHRAE equations.
3 free calculations
Velocity, Reynolds number, friction factor, head loss and pressure drop for each segment of the critical hydronic circuit.
3 free calculations
Water or air horsepower, brake horsepower, input kW, standard motor size, annual energy and the affinity laws.
3 free calculations
NPSH available from the site elevation, liquid temperature, static height and suction losses, with the margin over the pump maker's NPSHr.
3 free calculations
Water supply sizing from your fixtures: fixture units, demand, Hazen-Williams friction, velocity and pressure at the critical fixture.
3 free calculations
Total drainage fixture units for fixtures picked by name and check them against the allowable DFU for the pipe; Manning full-flow capacity shown for information.
3 free calculations
Roof and storm drain checks from your roof area and rainfall rate: design flow by Equation 11-1 and a pass/fail for each leader, drain and sewer.
3 free calculations
Gas pipe sizing by the IFGC 402.4 low- and high-pressure equations (longest-length method) for natural gas and LP in Schedule 40 steel, copper tube Type K/L and PE.
3 free calculations
Storage volume, recovery and input for a peak period, or tankless input for a peak flow, in Btu/h and kW.
3 free calculations
Design flow, total dynamic head, basin working volume and pump-down depth, with an optional pump-curve check.
3 free calculations
Pressure wave speed, critical closure time, Joukowsky or slow-closure surge, and maximum and minimum pressure against the rating.
3 free calculations
Length change between anchors and the expansion loop or offset length for copper, PVC, CPVC and steel pipe.
3 free calculations
System curve, Darcy or Hazen-Williams friction, and optional NPSHa.
3 free calculations
Solve sprinkler flow, pressure or K-factor from Q = K sqrt(P), with the NFPA 13 7 psi minimum.
3 free calculations
Sprinklers in the design area, remote sprinkler flow and pressure, hose allowance, duration and water volume.
3 free calculations
Pitot flow, available flow at 20 psi residual and the water supply curve, with a demand check.
3 free calculations
Class A extinguisher count by floor area and 75 ft travel, and Class B travel distance by rating.
3 free calculations
Occupant load by space from Table 1004.5, minimum exits per story and egress capacity width.
3 free calculations
Not sure which app fits? Browse by discipline or try a worked example. Browse disciplines →