OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Open Channel Flow Calculator Manning's equation, normal and critical depth

This app is temporarily unavailable.
Method, assumptions and limits (read before use)
  • Method: Manning Q = (KU/n) A R2/3 S1/2 with KU = 1.49 (US; HDS-5 Eq. 3.4b, TR-55; Chow uses 1.486, a 0.3% difference). Section geometry per Chow (1959) Table 2-1. Normal and critical depth by bisection (fixed iterations, deterministic). Froude number Fr = V/√(gA/T); critical depth Q2/g = A3/T. US customary units only.
  • Assumptions: straight prismatic channel in steady uniform flow, one Manning n over the whole perimeter, bed slope = friction slope, energy coefficient α = 1, g = 32.2 ft/s2, water unit weight 62.4 lb/ft3.
  • Not covered: backwater / gradually varied flow, composite or compound channels, freeboard, lining stability (shear output gives stresses only; compare with the permissible shear of your lining). Chow's published critical depth for Example 10-1 (2.22 ft) uses α = 1.10; this page uses α = 1 and shows 2.15 ft.
  • Circular pipes: open-channel discharge peaks at 1.0757 × full-flow Q (y/D = 0.938). The lowest (stable) depth is returned; a Q above that maximum is rejected. Above y/D = 0.82 flow is flagged as unstable. Critical depth is capped at the diameter.
  • Required fields: shape, solve-for, S and n have no defaults. Fields that do not apply to the chosen shape are ignored with a warning. Misspelled or unknown fields are rejected, not ignored. Inputs outside sane bounds (Q up to 10,000,000 cfs, S 1e-8 to 1, n 0.005 to 0.3, b 0.1 to 1000 ft, z up to 20, D 1 to 1200 in, depth 0.001 to 1000 ft) are rejected.
  • Checks: warnings for slope above 0.15 (percent entered by mistake?), n outside 0.011 to 0.1, velocity above 15 ft/s, Froude number 0.9 to 1.1 (near critical), supercritical flow, steep side slopes, very wide channels and circular depths above y/D 0.82.
Detailed calculation inputs (shape, mode, slope, n, section, Q or depth; Q can also come from a Rational Method result)

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

Related apps

  • Gutter Spread & Inlet Capacity
  • Outlet Structure Rating
  • Riprap Outlet Protection
  • Grass-Lined Channel & Swale
  • Storm Pipe Sizing
  • All Civil / Site apps
OTWapps
About Methods & references View plans Privacy Terms

Engineering aid only. Professional verification required.