Civil / Site

Stormwater, grading and site access

New to these tools?Try a worked example →

Choose an app

How these tools work

Full Site and Stormwater DesignBeta

NRCS NEH 630 / TR-55, FHWA HEC-22, NOAA Atlas 14, FDOT

NRCS curve number and unit hydrograph, Muskingum-Cunge reaches, storage-indication ponds

Members: OTW Pro or OTW Team

Paid plan

Open app →

Peak Runoff (Rational Method)

Q = CiA; Tc per TR-55/FDOT

Rational Method peak flow Q = CiA with weighted C, IDF input and Tc by Kirpich, TR-55 or FDOT kinematic wave; 5-min floor default.

3 free calculations

Open app →

Stormwater Runoff (TR-55)

NRCS TR-55 (1986), curve number runoff & peak discharge

NRCS TR-55: composite curve number, runoff depth, time of concentration by segment, and graphical peak discharge.

3 free calculations

Open app →

Earthwork Cut & Fill

Average end area / prismoidal

Cut and fill volumes by average end area or cross-section coordinates, prismoidal correction, shrink and swell, mass diagram, grid method.

3 free calculations

Open app →

Outlet Structure Rating

FHWA HEC-22, orifice & weir stage-discharge

Outlet structure rating per HEC-22 Ch. 10: orifice, weir, V-notch and riser flow, composite stage-discharge, tailwater submergence.

3 free calculations

Open app →

Riprap Outlet Protection

FHWA HEC-14, apron & basin

HEC-14 riprap outlet protection for culverts and pipes: apron or basin, stone size D50, length, width, thickness, gradation class.

3 free calculations

Open app →

Grass-Lined Channel & Swale

FHWA HEC-15, vegetative lining

HEC-15 grass-lined swale and roadside ditch design: normal depth, velocity, Froude number, permissible shear of the grass and soil, freeboard and maximum discharge.

3 free calculations

Open app →

ADA Ramp Slope

2010 ADA Standards & PROWAG 2023

Check ramps, walking surfaces and curb ramps against the 2010 ADA Standards or PROWAG 2023: slopes, landings, widths, handrails.

3 free calculations

Open app →

Storm Pipe Sizing

Manning full and partial flow

Storm pipe and box sizing by Manning full and partial flow: required diameter, next standard size, normal and critical depth, velocity checks.

3 free calculations

Open app →

Culvert Capacity & Sizing

FHWA HDS-5 inlet and outlet control

Culvert inlet and outlet control per FHWA HDS-5: governing headwater, HW/D checks, outlet velocity and size selection.

3 free calculations

Open app →

Detention Pond Routing

Storage-indication (modified Puls), HEC-22

Detention pond routing by the storage-indication (modified Puls) method per FHWA HEC-22 and HDS-2: inflow hydrograph, stage-storage, orifice, weir and spillway outlets.

3 free calculations

Open app →

Open-Channel Flow

Manning normal and critical depth

Open-channel Manning flow for trapezoid, rectangle, triangle and circular sections: normal depth, discharge, velocity, Froude number and critical depth.

3 free calculations

Open app →

Pavement Design

AASHTO Guide for Design of Pavement Structures (1993)

AASHTO 1993 pavement design: flexible structural number and layer thicknesses, rigid slab thickness, and design ESALs from axle loads.

3 free calculations

Open app →

Vertical Curves

AASHTO A Policy on Geometric Design of Highways and Streets, 7th edition (2018)

AASHTO Green Book 2018 crest and sag vertical curves: stopping and passing sight distance, K values, minimum length, PVC/PVT stations, high or low point and profile elevations.

3 free calculations

Open app →

Sanitary Sewer

Ten States Standards, Recommended Standards for Wastewater Facilities (2014)

Ten States Standards and ASCE MOP 60 sanitary sewer capacity: average and peak flow, infiltration/inflow, depth and velocity at peak, average and minimum flow, minimum slope, and pipe size selection.

3 free calculations

Open app →

Parking

2010 ADA Standards 208.2 and stall/aisle layout

Parking app: required spaces from the ratios you enter (mixed uses, shared parking), accessible and van spaces per the 2010 ADA Standards 208.2, EV-ready count and a stall and aisle layout check for 90, 60, 45 and 30 degree parking. No local code table is built in.

3 free calculations

Open app →

Fire Service Line

NFPA 13 / NFPA 24 hydraulics to the base of the riser

Fire service line hydraulics, NFPA 13 and NFPA 24 practice: Hazen-Williams friction with equivalent lengths, backflow and meter losses, elevation, hydrant flow test supply curve (N^1.85) and the safety margin at the base of the riser.

3 free calculations

Open app →

Modified Rational Detention

FHWA HEC-22 / agency Modified Rational Method

Modified Rational Method detention volume: critical storm duration search with inflow trapezoid, allowable release (entered or pre-development Rational peak), documented outflow assumption, duration table and step-by-step citations.

3 free calculations

Open app →

Lift Station

Hazen-Williams; wet well V = TQ/4

Force main losses and velocity, total dynamic head, wet well volume and pump levels, cycle time, detention, pump operating point and buoyancy.

3 free calculations

Open app →

Full Lift Station DesignBeta

Hazen-Williams; wet well V = TQ/4; pump and system curves

Duplex or triplex submersible station: pump and system curves, wet well levels, cycle time, force main checks and a sheet set

Members: OTW Pro or OTW Team

Paid plan

Open app →