Full Site and Stormwater DesignBeta
NRCS NEH 630 / TR-55, FHWA HEC-22, NOAA Atlas 14, FDOTNRCS curve number and unit hydrograph, Muskingum-Cunge reaches, storage-indication ponds
Members: OTW Pro or OTW TeamPaid plan
Stormwater, grading and site access
NRCS curve number and unit hydrograph, Muskingum-Cunge reaches, storage-indication ponds
Members: OTW Pro or OTW TeamPaid plan
Rational Method peak flow Q = CiA with weighted C, IDF input and Tc by Kirpich, TR-55 or FDOT kinematic wave; 5-min floor default.
3 free calculations
NRCS TR-55: composite curve number, runoff depth, time of concentration by segment, and graphical peak discharge.
3 free calculations
Cut and fill volumes by average end area or cross-section coordinates, prismoidal correction, shrink and swell, mass diagram, grid method.
3 free calculations
HEC-22 gutter flow and spread, and grate, curb-opening, slotted and combination inlet capacity on grade and in sags, with bypass.
3 free calculations
Outlet structure rating per HEC-22 Ch. 10: orifice, weir, V-notch and riser flow, composite stage-discharge, tailwater submergence.
3 free calculations
HEC-14 riprap outlet protection for culverts and pipes: apron or basin, stone size D50, length, width, thickness, gradation class.
3 free calculations
HEC-15 grass-lined swale and roadside ditch design: normal depth, velocity, Froude number, permissible shear of the grass and soil, freeboard and maximum discharge.
3 free calculations
Check ramps, walking surfaces and curb ramps against the 2010 ADA Standards or PROWAG 2023: slopes, landings, widths, handrails.
3 free calculations
Storm pipe and box sizing by Manning full and partial flow: required diameter, next standard size, normal and critical depth, velocity checks.
3 free calculations
Culvert inlet and outlet control per FHWA HDS-5: governing headwater, HW/D checks, outlet velocity and size selection.
3 free calculations
Detention pond routing by the storage-indication (modified Puls) method per FHWA HEC-22 and HDS-2: inflow hydrograph, stage-storage, orifice, weir and spillway outlets.
3 free calculations
Open-channel Manning flow for trapezoid, rectangle, triangle and circular sections: normal depth, discharge, velocity, Froude number and critical depth.
3 free calculations
AASHTO 1993 pavement design: flexible structural number and layer thicknesses, rigid slab thickness, and design ESALs from axle loads.
3 free calculations
AASHTO Green Book 2018 crest and sag vertical curves: stopping and passing sight distance, K values, minimum length, PVC/PVT stations, high or low point and profile elevations.
3 free calculations
Ten States Standards and ASCE MOP 60 sanitary sewer capacity: average and peak flow, infiltration/inflow, depth and velocity at peak, average and minimum flow, minimum slope, and pipe size selection.
3 free calculations
Parking app: required spaces from the ratios you enter (mixed uses, shared parking), accessible and van spaces per the 2010 ADA Standards 208.2, EV-ready count and a stall and aisle layout check for 90, 60, 45 and 30 degree parking. No local code table is built in.
3 free calculations
Fire service line hydraulics, NFPA 13 and NFPA 24 practice: Hazen-Williams friction with equivalent lengths, backflow and meter losses, elevation, hydrant flow test supply curve (N^1.85) and the safety margin at the base of the riser.
3 free calculations
Modified Rational Method detention volume: critical storm duration search with inflow trapezoid, allowable release (entered or pre-development Rational peak), documented outflow assumption, duration table and step-by-step citations.
3 free calculations
Force main losses and velocity, total dynamic head, wet well volume and pump levels, cycle time, detention, pump operating point and buoyancy.
3 free calculations
Duplex or triplex submersible station: pump and system curves, wet well levels, cycle time, force main checks and a sheet set
Members: OTW Pro or OTW TeamPaid plan