OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Pavement Design Calculator AASHTO Guide for Design of Pavement Structures (1993)

AASHTO Guide for Design of Pavement Structures (1993)
This app is temporarily unavailable.

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

US customary units (in, psi, pci, kips).

Method, assumptions and limits
  • Method: AASHTO Guide for Design of Pavement Structures (1993). Flexible: the design equation (Part II Sec 3.1.1, Fig 3.1) is solved for the structural number SN from W18, reliability (ZR), S0, ΔPSI and the roadbed resilient modulus MR; the layered design uses SN = a1D1 + a2D2m2 + a3D3m3 and the layer-protection method (Fig 3.2). Rigid: the slab equation (Sec 3.2.1, Fig 3.7) is solved for the thickness D from W18, ZR, S0, ΔPSI, pt, S′c, Cd, J, Ec and k. ESAL helper: Appendix D load equivalency factors for single, tandem and tridem axles. US units. Both equations are solved by deterministic bisection (no nomograph reading).
  • Required inputs, no hidden defaults: reliability (percent, or ZR), S0, pt, MR (flexible), layer coefficients a, drainage coefficients m, layer moduli, and for rigid S′c, Cd, J, Ec, k. Only these have defaults, each echoed and warned: initial serviceability p0 (4.2 flexible, 4.5 rigid), traffic growth (0 %), and the rounding increments (surface 0.5 in, base and subbase 1 in, slab 0.5 in).
  • Layer-protection design: SN1 is solved with the base modulus as the roadbed value, D1 ≥ SN1/a1; a subbase SN2 uses the subbase modulus; the last layer takes the rest of the SN with the subgrade modulus. Thicknesses are rounded up to the stated increment (never down), so the as-built SN is at least the required SN at every interface; the as-built SN and W18 capacity are reported. This is the minimum-thickness design; no layer is optimized for cost. The FHWA NHI-05-037 example rounds to the nearest 0.5 in and 1 in, so its 14.3 in base is 14 in there and 15 in here (14 in is 0.05 SN short). The Fig 3.7 rigid example reading of 9.75 in is a secondary (chart) reading: the equation solves 9.560 in for 5.1 million ESAL, so the 10.0 in design is correct.
  • Minimum thicknesses: your agency minimum goes in layers.<layer>.min_in or rigid.min_thickness_in and is applied. Guide Table 3.2 (suggested minimums by ESAL) is an advisory check and warning only. A layered design is checked against your minimums (every layer at least its min_in, surface and base not 0 in); a result in which no gating check ran (no layers given, the ESAL helper) is shown as NOT EVALUATED, never as a pass.
  • Traffic: W18 is the design-lane ESAL total for the whole design life (give traffic.esal) or computed from axle groups (traffic.axles: axle type single / tandem / tridem, group load in kips, design-lane passes in year 1, design years, growth rate). The load equivalency factor depends on SN or D, so SN or D is iterated to convergence unless you give assumed_SN or assumed_D_in. The reliability enters only through ZR S0; do not also inflate the ESAL.
  • Limits and out of scope: an empirical method calibrated to the AASHO Road Test, not mechanistic-empirical (no MEPDG). No overlay or rehabilitation design, seasonal-MR averaging, k-value correlation from subbase and bedrock (enter the effective k), frost heave or swell, drainage design beyond the m and Cd you enter, JRCP/CRCP reinforcement, or local agency catalogs. W18 below 50,000 ESAL is warned (low-volume roads need an agency method); an axle-derived W18 above 1e10 ESAL is rejected. At 99.99 % reliability the exact ZR = -3.719 is used (the Guide table prints -3.750, about 0.02 to 0.03 in SN): enter ZR directly to follow the table.
  • Inputs are strict: numeric values must be numbers (text is rejected); misspelled or unknown fields are rejected with a suggestion; a null is rejected (leave the field out); values are range-checked and unusual ones are warned. Labels are at most 80 characters and meta at most 20 entries. Results are engineering aids; a licensed engineer must review before sealing.

Related apps

  • Vertical Curves
  • Full Site and Stormwater Design
  • Peak Runoff (Rational Method)
  • Stormwater Runoff (TR-55)
  • Earthwork Cut & Fill
  • All Civil / Site apps
OTWapps
About Methods & references View plans Privacy Terms

Engineering aid only. Professional verification required.