OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Riprap Outlet Protection Calculator FHWA HEC-14, apron & basin

FHWA HEC-14
This app is temporarily unavailable.

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

Method, assumptions and limits
  • Method: FHWA HEC-14 3rd ed. (FHWA-NHI-06-086) Chapter 10 for the outlet of a culvert or pipe. You choose apron (Sec. 10.2) or basin (Sec. 10.1). US units (ft, in, cfs, fps).
  • Apron: D50 = 0.2 D (Q / (sqrt(g) D^2.5))^(4/3) (D / TW) (Eq 10.4, Fletcher and Grace 1972; circular culverts). TW is limited to 0.4 D to 1.0 D (0.4 D if unknown); supercritical flow uses D' = (D + yn)/2 (Eq 10.5). The class is the smallest with D50 at least the required size; length (4 D to 8 D), depth (3.5 D50 to 2.0 D50) and width (3 D + 2L/3) come from Table 10.1 (an example table of the FHWA Central Federal Lands Highway Division: enter your agency classes in "apron_classes"). A box culvert uses the UD&FCD equation D.1b of Appendix D and is flagged, because HEC-14 gives Eq 10.4 for circular culverts only. The Appendix D equations (UD&FCD, Berry, Searcy, Bohan/USACE) are listed as a cross-check, not used for the design.
  • Basin: hs/ye = 0.86 (D50/ye)^-0.55 (Vo / sqrt(g ye)) - Co (Eq 10.1; Co from Eq 10.2 envelope or Eq 10.3 best fit), then Ls = 10 hs (not less than 3 Wo), LB = 15 hs (not less than 4 Wo), WB = Wo + 2 LB/3, the exit critical depth and velocity against the allowable velocity, the checks hs/D50 at least 2 and D50/ye at least 0.1, and the thickness 2 D50 or 1.5 Dmax. Each stone size you list is checked, plus the largest D50 that still gives hs/D50 = 2.
  • High tailwater (basin TW/yo above 0.75, apron TW above 1.0 D): the extent of protection downstream uses the Fig. 10.3 centerline-velocity decay and Eq 10.6 (Searcy). The chart is represented by VL/Vo = 6/(L/De), a fit to the four values read in the HEC-14 examples (within 5 %): an estimate to check against the chart.
  • Gradation: the NCHRP Report 568 class (I to X, used by FHWA HEC-23) by the "next larger" method: the smallest class whose minimum d50 is at least the design D50, with its d15, d50, d85, d100 and weights.
  • Stone specific gravity is an input (default 2.65, with a warning): Eq 10.4 assumes 2.65 and D50 is adjusted inversely to the specific gravity. The tailwater, outlet depth and velocity must come from your culvert analysis (HEC-14 Fig. 3.3/3.4, or the Culvert app: paste its result in "culvert_result", read only). The basin must be sized with the lowest tailwater of the range.
  • Not covered: outlet scour estimates (HEC-14 Ch. 5), other dissipators, grouted riprap, the filter or bedding layer and the toe detail, channel degradation. The basin tests covered 0.1 to 100 cfs; larger flows are an extrapolation (as in the HEC-14 examples) and are warned.
  • Bounds: unknown or misspelled keys are rejected (with a suggestion); numeric values must be numbers; sizes and flows are range-checked; the free-form "meta" is limited to 20 entries, keys up to 60 characters and text values up to 200 characters, numbers below 1e15 in absolute value, with no nesting. Engineering aid only. Professional verification required.