OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Outlet Structure Calculator Orifice and weir stage-discharge, FHWA HEC-22

FHWA HEC-22
This app is temporarily unavailable.

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

Method, assumptions and limits
  • Method: each outlet is evaluated independently at every stage and the discharges are added (FHWA HEC-22 4th ed., FHWA-HIF-24-006, Ch. 10, Sec. 10.3.3.1 to 10.3.3.5, Table 10.10). US units (ft, in, cfs); stage is a water-surface elevation in ft.
  • Orifice: Q = Co A sqrt(2 g h) (Eq 10.23), h to the centroid of the opening; circular or rectangular; several identical openings by count. Below the crown the opening is only partly covered: the exact flow is integrated and scaled to meet Eq 10.23 at the crown (HEC-22 itself applies Eq 10.23 at every stage). With a tailwater above the centroid the head is HW - TW (Fig. 10.16).
  • Weirs: Q = Cw sqrt(2 g) [(L - 0.1 N h) h^1.5 + 0.8 Z h^2.5] (Eq 10.32/10.33; N end contractions, side slope Z:1). V-notch: Cw sqrt(2 g) tan(theta/2) h^2.5. Riser top: the lower of the weir (crest length pi D) and orifice flows (Example 10.11). Submerged weirs: Eq 10.34 factor (1 - (h2/h1)^m)^0.385.
  • End-contraction limit (Eq 10.33): L - 0.1 N h is a small correction to the Francis formula. Used unchanged at large heads it would make the discharge peak at h = 6L/N and fall to zero at h = 10L/N, which is impossible. The app applies it only while 0.1 N h ≤ 0.2 L (h ≤ 2L/N, e.g. a 1-ft slot with two contractions up to 1 ft of head). Above that head the deduction is held at 0.2 L (effective length 0.8 L), so the discharge never falls and never reaches zero; those stages are marked in the column weir_limit_exceeded, a warning is added and the check "within Eq 10.33 applicability" fails (overall result: CHECKS FAIL). The value above the limit is a stand-in, not a validated discharge. Do not use it for freeboard, stage or release sizing (the real discharge of a contracted sharp weir above 2L/N is not given by HEC-22, and the stand-in may be above or below it): use fewer contractions, a longer weir, a lower stage range or a tested rating table.
  • Stage for a given discharge: the first stage at which the composite rating reaches the discharge (a scan from the lowest invert, then bisection); it does not assume a monotone rating and warns if the rating ever falls.
  • Coefficients: you enter them. Where you leave one blank the HEC-22 value is used (Cd = Co = 0.60; Cw 0.37 sharp, 0.33 broad-crested, 0.31 V-notch) and every default is listed in the warnings and in "parameters used". Sharp vs broad-crested must be chosen.
  • Table 10.10 (published check): the book's composite adds an emergency spillway that it gives only as numbers (0, 39.55 and 55.8 cfs at 38.1, 38.7 and 39.4 ft). The sample (orifice + riser) therefore matches the book totals up to 38.1 ft only (the book's stages are rounded to 0.1 ft; at the printed stages the difference is up to 0.40 cfs, 3.7 %, at 36.1 ft because the discharge changes about 8 cfs per ft there); above 38.1 ft add those three book values as a rating table to compare with 62.55 and 80.69 cfs.
  • Rating tables: use one for a culvert or pipe barrel (headwater vs discharge from the Culvert app) or any device not modeled here. Linear interpolation, zero below the first stage, held at the last value above it (flagged and the check fails). "via" passes a group of structures through a barrel table: the group passes the smaller of its sum and the barrel capacity.
  • Tailwater: one constant elevation (or free outfall). Not modeled: dynamic tailwater or backwater, interaction between openings, barrel head loss inside a riser, flap gates, debris clogging (reduce the area or the coefficient yourself), orifice flow in a gate with a bottom contraction.
  • Bounds: unknown or misspelled keys are rejected (with a suggestion); numeric values must be numbers (text such as "6" is rejected); a null anywhere is rejected: tailwater, stage, stage list, stage_for_Q_cfs, the whole meta object, and any structure field such as Cw, Cd, Co, via, riser crest length or side slope (leave the field out: free outfall, the default coefficient, crest length pi D, Z = 0; an omitted riser crest length or coefficient is listed as a default and warned); sizes, elevations and coefficients are range-checked; labels are at most 80 characters; a total discharge above 10,000 cfs gets a plausibility warning and above 10,000,000 cfs is rejected. Engineering aid only. Professional verification required.