OTWapps
OTWapps
All apps
HomeSearch
Civil / Site
Full Site and Stormwater DesignPeak Runoff (Rational Method)Stormwater Runoff (TR-55)Earthwork Cut & FillGutter Spread & Inlet CapacityOutlet Structure RatingRiprap Outlet ProtectionGrass-Lined Channel & SwaleADA Ramp SlopeStorm Pipe SizingCulvert Capacity & SizingDetention Pond RoutingOpen-Channel FlowPavement DesignVertical CurvesSanitary SewerParkingFire Service LineModified Rational DetentionLift StationFull Lift Station Design
Structural
Wind Main Frame (MWFRS)Wind Components & Cladding (C&C)Load CombinationsLive LoadsWood BeamWood ColumnJoist & Rafter SpanSteel BeamSteel ColumnSeismic Base ShearSpread FootingCantilever Retaining WallTruss AnalysisSign StructuresSnow LoadsWood Shear Wall & DiaphragmConcrete VolumeRebar Weight & QuantityConcrete BeamCrane Runway BeamHelical Piles and AnchorsSolar Roof AttachmentTilt-Up Wall PanelSolar Ground-Mount PileFence and Freestanding Wall Wind
Electrical
Voltage DropPower Factor CorrectionDwelling Service LoadLighting (Lumen Method)Conductor Ampacity & SizingTransformer Size & ProtectionAvailable Fault CurrentBox FillConduit FillMotor Branch CircuitGrounding Conductor SizingPhotometric Analysis & Lighting LayoutPV String SizingConductor Resistance and Impedance
Mechanical
Duct SizingExhaustVentilationPsychrometricsHydronic Pipe Pressure DropPump and Fan PowerNPSH Available
Plumbing
Water Supply SizingDrain Fixture UnitsStorm/Roof DrainGas Pipe SizingWater Heater SizingSump Pump SizingWater Hammer (Surge)Pipe Thermal Expansion and Loop
Fire Protection
Sprinkler K-FactorSprinkler Design Area & DemandHydrant Flow Test & Supply CurveFire Extinguisher PlacementOccupant Load
AboutPricingAccount

Psychrometrics Calculator ASHRAE Handbook—Fundamentals 2017 (SI), Ch. 1 equations; Hyland & Wexler (1983)

ASHRAE Handbook—Fundamentals 2017 (SI), Ch. 1 equations

Result

Result not calculated

Confirm the inputs and the method notes before using the result.

How this result was calculated

Inputs & units
Method & assumptions
References & limitations
Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.

By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.

Your calculation

▤Result not calculatedComplete the inputs and review before calculating.

Downloads

Review inputs, calculation steps, and assumptions in one report.

US customary (°F, psia, ft) or SI (°C, kPa, m): pick the units first.

How this calculation works

Equations only: the ideal-gas moist-air equations of ASHRAE Handbook—Fundamentals 2017 (SI), Ch. 1, with the Hyland & Wexler (1983) saturation-pressure formulas. No chart or table is read.

  • Enter the dry bulb and exactly one second property: relative humidity, wet bulb, dew point or humidity ratio.
  • Pressure: enter the barometric pressure or the elevation (standard atmosphere, ASHRAE Handbook—Fundamentals 2017 (SI), Ch. 1 Eq. 3), not both. With neither, 101.325 kPa (14.696 psia) is used.
  • W = 0.621945 pw / (p - pw); h = 1.006 t + W (2501 + 1.86 t) (SI); v = 0.287042 (t + 273.15)(1 + 1.607858 W) / p.
  • Wet bulb and dew point are found by bisection on the same equations, so results can differ from a chart in the last digit.
  • Ranges: dry bulb -60 to 90 °C (-76 to 194 °F); pressure 50 to 110 kPa (7.25 to 15.95 psia); elevation -500 to 5000 m.

Related apps

  • Exhaust
  • Ventilation
  • Duct Sizing
  • Hydronic Pipe Pressure Drop
  • Pump and Fan Power
  • All Mechanical apps
OTWapps
About Methods & references View plans Privacy Terms

Engineering aid only. Professional verification required.