Engineering aid only. Professional verification required. The method notes and tags on this page are the references this app cites.
By running a calculation you agree to the Terms of Use and Privacy Policy. Results are preliminary and must be verified by a licensed professional.
Method, assumptions and limits
Method: FHWA HEC-22 4th ed. (FHWA-HIF-24-006, Feb 2024): gutter flow and spread by Izzard (Eq 5.2), composite gutters (Eq 5.5 to 5.8), V-shaped roadside gutters (Example 5.3); inlet interception on grade (Eq 7.1 to 7.13, splash-over from Figure 7.8) and in sags (weir/orifice, Eq 7.14 to 7.21); clogging and bypass carryover down a series of inlets. US units (ft, in, cfs, fps).
Figure 7.8: the splash-over velocity Vo is read from a digitized copy of the chart: about +/-0.15 fps below 3 ft and about +/-0.3 fps from 3 to 4.5 ft, where the three middle curves converge and the 30-degree and 45-degree curves cannot be told apart with certainty (the P-1-7/8 family can be off by up to 0.35 fps at 0.5 ft). Enter your own Vo (tested or manufacturer value) to override it. Version 0.1.2 re-digitized the 45-degree tilt-bar, reticuline, curved-vane (4 to 4.5 ft) and 30-degree tilt-bar (3 to 4.5 ft) curves.
Sag capacity step: for a curb opening HEC-22 uses the lower of the weir and orifice flows between d + a = h and 1.4 h, and the orifice equation alone above 1.4 h (slotted inlet: 2 to 5 in, then orifice). The capacity never decreases with depth, but it is not continuous at 1.4 h (5 in): it steps up there when the orifice flow is above the weir flow (for a depressed opening typically 15 % and up to 70 % or more; for an undepressed one about 4 %). HEC-22 gives no transition above that point, so the numbers are not smoothed; one depth is reported for every flow inside the step, and a warning gives the size of the step and the depth that continuing the lower-of-weir-and-orifice rule would give.
Inputs are strict: unknown or misspelled fields are rejected with a suggestion; a null is rejected in the case, gutter and inlet objects (leave the field out), but a null value inside meta (free-form project information, never used in a calculation) is accepted; an inlet.grate / curb / slot object that the chosen inlet type does not use is rejected, not ignored; location, section and clog_scope must be one of their listed words; labels are at most 80 characters and meta at most 20 entries; lengths, widths, slopes and coefficients are range-checked; fields that do not apply to the chosen section are listed in the warnings. A curb depression a_in that is not less than the opening height h_in is flagged. Clogging is an input you must choose (a sag result with none entered is the UNCLOGGED capacity).
Not modeled: flow in the street beyond the gutter section (inverted crown, median ditches), grate or curb inlets with other geometries, inlet-to-inlet interference other than the carryover, pavement ponding hydraulics beyond the allowable spread, and hydroplaning checks. A spread above 40 ft is flagged as implausible. Engineering aid only. Professional verification required.