Rational Method peak runoff (Q = CiA) with a worked example
How to use the Rational Method: composite runoff coefficient, time of concentration with the Kirpich equation, rainfall intensity from an IDF curve, and Q = CiA in cfs.
Run this in the free Peak Runoff (Rational Method) appThe Rational Method estimates the peak runoff rate from a small drainage area. It is the standard starting point for sizing inlets, storm pipes and small ditches.
The equation
Q = C i A
- Q: peak flow, cfs
- C: runoff coefficient (dimensionless)
- i: rainfall intensity for the design storm, in./hr, at a duration equal to the time of concentration
- A: drainage area, acres
In U.S. units the conversion factor is 1.008, which is taken as 1.0.
Step 1: Composite runoff coefficient
Weight each surface's C by its area. Use the C table your reviewing agency requires; the values below are example inputs only.
| Surface | Area (ac) | C | C × A |
|---|---|---|---|
| Roof and pavement | 1.5 | 0.95 | 1.425 |
| Lawn | 2.5 | 0.20 | 0.500 |
| Total | 4.0 | 1.925 |
Composite C = 1.925 / 4.0 = 0.48
Step 2: Time of concentration (Kirpich)
tc = 0.0078 L0.77 S−0.385 (minutes; L = flow length in ft, S = slope in ft/ft)
For L = 800 ft and S = 0.015: tc = 0.0078 × 8000.77 × 0.015−0.385 = 6.8 min. Many agencies set a minimum tc (often 5 or 10 minutes); use the larger value. Kirpich was developed for small rural channels; TR-55 segment methods (sheet, shallow concentrated and channel flow) are often required instead for developed sites.
Step 3: Rainfall intensity
Read i from the IDF curve or NOAA Atlas 14 data for your site at the design return period and a duration equal to tc. For this example we use i = 5.5 in./hr (example value).
Step 4: Peak flow
Q = 0.48 × 5.5 × 4.0 = 10.6 cfs
Limits
- The method assumes uniform rainfall over the whole area for at least tc. It is meant for small areas; HEC-22 cites roughly 200 acres as an upper limit, and many agencies set lower limits.
- It gives a peak flow only, not a hydrograph or volume. Detention design needs a hydrograph method or the Modified Rational Method.
- Some agencies increase C for less frequent storms (frequency factors). Follow your local criteria.
Run it in the app
The free Peak Runoff (Rational Method) app does this calculation in your browser, shows each intermediate value and cites the code section on each line. You can try 3 calculations without an account. A free account is needed after that, and to download results.
Frequently asked questions
What units does Q = CiA use?
With i in inches per hour and A in acres, Q comes out in cubic feet per second. The exact conversion factor is 1.008, normally taken as 1.0.
What rainfall duration should I use?
Use the intensity for a storm duration equal to the time of concentration of the drainage area, at the design return period.
Can the Rational Method size a detention pond?
No. It gives only a peak flow. Use the Modified Rational Method, TR-55/TR-20 or another hydrograph method for storage design.
References
FHWA HEC-22, Urban Drainage Design Manual (Rational Method and time of concentration); Kirpich (1940); your agency's IDF data and runoff coefficient tables. Values above are quoted for illustration; check them against the edition adopted in your jurisdiction.
Related apps
- Peak Runoff (Rational Method)
- Stormwater Runoff (TR-55)
- Storm Pipe Sizing
- Gutter Spread & Inlet Capacity
More guides
- How to calculate conduit fill under NEC 2023 Chapter 9
- How to calculate voltage drop with NEC Chapter 9 tables
- ASCE 7-22 velocity pressure and components and cladding pressure: a worked example
- Sprinkler K-factor: Q = K√P, with the 7 psi minimum
- How to calculate box fill under NEC 2023 314.16
Published 2026-11-12.