- Which standard does the column base plate calculator use?
- AISC 360-22 Section J8 for concentric axial load, using the plate thickness procedure in AISC Design Guide 1. Yield strength follows the ASTM grade you select.
- What load does it check?
- Concentric axial load on a rectangular plate, factored or allowable. A small-moment check is included and is marked draft.
- What units does it use?
- US customary units: inches, kips, and ksi.
- What is outside this check?
- Anchor design to ACI 318 Chapter 17 is out of scope. If the pedestal area is blank, bearing uses the plate area with no increase. The rod count shown is not a designed anchorage.