Pump Total Dynamic Head (TDH) Calculator System curve, Darcy or Hazen-Williams, NPSHa
Pump total dynamic head and system curve. Pipe C is a cited preset. Roughness is never filled in. Fitting K is yours to enter (no Crane table is loaded). Manning n can be shown from its preset and is not used in the head.
UnitsIP (gpm, ft, in) SI (L/s, m, mm)
Friction methodHazen-Williams Darcy-Weisbach
Pipe material (C)Enter C Unlined cast or ductile iron (C 100) Cement-lined cast or ductile iron (C 140) Black or galvanized steel, wet (C 120) Black or galvanized steel, dry (C 100) Plastic, listed (C 150) Copper, brass, or stainless (C 150) Asbestos cement (C 140) Concrete (C 140)
Hazen-Williams C
Roughnessuser entered; no cited roughness preset
Manning n preset (not used)None Concrete box culvert (n 0.012) Concrete pipe (n 0.012) Metal pipe, helical, 12-24 in (n 0.02) Metal pipe, helical, 30-54 in (n 0.022) Metal pipe, helical, 60 in and larger (n 0.024) Metal pipe, spiral rib (n 0.012) PVC, smooth interior (n 0.012) Polyethylene, single wall (n 0.024) Polyethylene, double wall smooth (n 0.012) Polypropylene, single wall (n 0.024) Polypropylene, double and triple wall smooth (n 0.012)
Static head
Design flow
Length
Inside diameter
Fitting name
Fitting count
Fitting Kuser entered
Fitting sideDischarge Suction
Fitting pipe indexrequired when that side has two pipes; a blank index is an error then
Second discharge length
Second discharge diameter
Suction length
Suction diameter
Water temperature1 C to 100 C (about 34 F to 212 F) for density, viscosity, and vapor pressure
Temperature presetCustom 40 50 60 70 80 100 140 180
Site elevation
Suction static head
Pump speed (rpm)
Load hand-calc example Calculate TDH
Engine response (unrounded)